158 Part Number 80-1230-9 10/10
2. Disconnect bin level probe from control board and
check continuity (ohms) from the female
connector to the bin level probe.
Continuity Cause
No Replace bin level probe.
Yes Go to step 3.
CHECK FOR CONTINUITY
CONNECTOR TO PROBE.