EasyManua.ls Logo

Manitowoc QF0400 - Page 180

Manitowoc QF0400
292 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
180 Part Number 80-1230-9 10/10
Hall Effect Switch Diagnostics
All diagnostics must be performed with the ice damper
installed and in the closed position. The control board
lights will not indicate as described below with the ice
damper in the open position. The ice damper must
swing freely, if the damper is binding adjust/loosen
screws that hold the Hall Effect Switch Housing in
place.
SWITCH FAILS OPEN OR IS DISCONNECTED
HES#1
1. Reset line voltage to the ice machine
2. Wait 5 minutes for delay to expire.
3. HES#1 light energizes and ice machine starts.
4. When 5 minute delay period ends the ice machine
shuts off and flashes the HES#1 light.
HES#2
1. Reset line voltage to the ice machine.
2. Wait 5 minutes for delay to expire.
3. HES#2 light is energized and HES#1 light is de-
energized.
4. Ice machine starts.
5. After 5 minutes the ice machine shuts off. HES#1
is de-energized and HES#2 is energized.

Table of Contents

Other manuals for Manitowoc QF0400

Related product manuals