Part Number 80-1230-9 10/10 279
Control Board Lights
#1 Nugget - Red, indicate the control is configured for
nugget ice machines.
#2 Flaker - Red, indicates the control is configured for
flaked ice machines.
#3 HES #1 - Green, works in conjunction with the Hall
Effect Switch #1. When the ice damper is closed the
light is on.
#4 HES #2 - Green, works in conjunction with the Hall
Effect Switch #2. When the ice damper is closed the
light is on.
#5 Clean - Yellow, indicates the unit is in a clean
sequence.
#6 Maint. - Red, indicates that maintenance is
required. Only used when configured for nugget.
#7 Water - Energizes when the water level in the
reservoir closes (raises) the float switch. De-energizes
when the float switch opens.
Racing Lights - All lights racing indicates a 5-minute
delay period is timing out.