42 Part Number: 040006847 12/19
Step 17 Replace all the removed parts, then turn on the
water supply switch.
Step 18 Place the toggle switch in the ON position, and
the ice machine will start a new ice making cycle.
NOTE: To terminate a clean cycle, press the toggle switch
in the WASH position and hold for more than 30 seconds.
,
Caution
If the cleaner/sanitizer solution has been poured into
the water trough, then the entire clean cycle must
be completed. Don’t terminate the cleaning cycle, or
the ice machine will not purge the remaining cleaner/
sanitizer solution from the water trough.