MR 150M–1050M SINGLE – MXIII CONTROLLER
OPERATION
23
Gallons Liters
Valve Address
Select Language xx x
System Size
Regen Type xx x
Valve Type xx x
Regenerant Flow xx x
Remote Signal Start xx x
Display Format xx x US - Gallons EU - Metric-Liters
Unit Capacity x x 1 - 9900000 Grains 1 - 198000 gCaCO3
Capacity Safety Factor x x
Feed Water Hardness x x 1 - 199 Grains/Gallons 1 - 1999 mgL
Trip Point 1 0 - 997gpm 0 - 3997 Lpm
Trip Delay 1 30 - 99 Seconds 30 - 99 Seconds
Trip Point 2 Trip Point 1 + 1 - 998 gpm Trip Point 1 + 1 - 3998 Lpm
Trip Delay 2 30 - 99 Seconds 30 - 99 Seconds
Trip Point 3 Trip Point 2 + 1 - 999 gpmTrip Point 2 + 1 - 3999 Lpm
Trip Delay 3 30 - 99 Seconds 30 - 99 Seconds
Regeneration Day Override xx x
Regeneration Time
x o o 12:00 a.m. - 11:59 p.m. 00:00 - 23:59 Hour
Cycle 1 xx x
Cycle 2 xx x
Cycle 3 xx x
Cycle 4 xx x
Cycle 5 xx x
Auxiliary Relay xx x
Aux Relay Output Start
cc c
Aux Relay Output End
cc c
Chemical Pump x x
CPO Aux Relay Volume
c c 1 - 999 gallons 0001 - 9999 Liters
CPO Aux Relay Time
c c 00:00:01 - 02:00:00 00:00:01 - 02:00:00
Flow Meter x x
Generic
x x
Maximum Flow Rate
a a 20 - 2000 GPM 20 - 2000 LPM
Add _ _ _ Gallons or Liters
a a 1 - 255 Gallons 001 - 255 Liters
Every _ _ _ Pulses
a a 552 - 1552 - 1
System Type
00:00:01 to Total Regeneration Time - 1
Start Time + 1 to Total Regeneration Time
Enabled, Disabled
Off, 1 - 99
00:00:00 - 04:00:00
Off, 00:00:
00 - 04:00:00
1" 1.5" Paddle or Turbine, 2" Paddle, 3" Paddle, Generic
Off, 00:00:00 - 04:00:00
Off, 00:00:00 - 04:00:00
Off, 00:00:00 - 04:00:00
Enabled, Disabled
2750, 2850, 2900, 3150, 3900, Stager
Downflow, Upflow, Upflow Fill First
Off, 00:00:01 - 01:39:00
0- 50%
Time Clock, Metered Delayed, Metered Immediate
Programming Parameter Ranges
4
Time
Clock
4
Metered
Immediate
4
Metered
Delayed
1
English, Espanol, Portugues, Deutsch, Francais
1
Programming Parameters and Ranges
a - If Generic Flow Meter is chosen, then programming parameters will be viewed.
c - All Relay Output parameters programming will be viewed if Enabled.
o - Regeneration Time will only be viewed if Regeneration Day Override is used
u - If Auxiliary Relay is Enabled then Chemical Pump Relay will not be viewed or if Chemical Pump Relay is
Enabled then Auxiliary Relay will not be viewed
*Indicates Required settings for Stager Controller
SINGLE (SYSTEM 4) PROGRAMMING AND RANGES