MR 150M–1050M
SINGLE SYSTEM 4
MX-III CONTROLLER
COMMERCIAL WATER CONDITIONERS
INSTALLATION, OPERATION,
AND MAINTENANCE MANUAL
MODEL NO:
SERIAL NO:
DATE INSTALLED:
DEALER:
COMPLETE FOR FUTURE REFERENCE:
Marlo Incorporated
2227 South Street
P.O. Box 044170
Racine, WI 53404-7003
www.Marlo-Inc.com
A2170381 8-313 R3
FOR MODELS MANUFACTURED
FROM OCTOBER 2017

Questions and Answers

  • F
    fbrewerSep 8, 2025
    Why is my MARLO MR-210-2 failing to draw brine?
    • J
      Joshua HamptonSep 8, 2025
      If your MARLO Controller fails to draw brine, check the water pressure. It must be at least 30 psi during regeneration.
  • J
    Joshua PenaAug 23, 2025
    Why is my MARLO MR-210-2 Controller showing a matching address error?
    • J
      Johnny NielsenAug 23, 2025
      The most likely cause of a matching address error in your MARLO Controller is having two or more units programmed with the same unit number. To resolve this, ensure that each unit has a unique unit number.
  • A
    Andrew CurtisAug 25, 2025
    Why is the display on my MARLO MR-210-2 Controller flashing?
    • V
      Vicki WarnerAug 25, 2025
      If the MARLO Controller display is flashing or blinking, it indicates that a power outage has occurred.
  • C
    Christopher MayAug 26, 2025
    How to fix a MARLO MR-210-2 Controller when no messages are displayed?
    • V
      vmooreAug 27, 2025
      If your MARLO Controller displays no messages or shows small black squares, adjust the contrast button located on the back of the unit until the text becomes visible.
  • M
    Michelle NewtonAug 27, 2025
    What does "Com Error" mean on my MARLO MR-210-2 Controller and how to fix it?
    • K
      karen94Aug 28, 2025
      A "Com Error" on your MARLO Controller indicates a communication error. To resolve this, check the system's wiring to ensure it is correct and that all connections are secure.
  • L
    lzunigaSep 22, 2025
    What causes loss of softening resin and gravel in service lines in MARLO MR-210-2 Controller?
    • K
      Katherine WhiteSep 22, 2025
      To resolve a loss of softening resin with evidence of resin and/or gravel in the service lines of your MARLO Controller, check for damage to the softener under-drain system.
  • R
    rhernandezSep 16, 2025
    What to do if the diaphragm valve does not close completely on my MARLO MR-210-2 Controller?
    • K
      Kaitlyn HarrisSep 16, 2025
      If the diaphragm valve on your MARLO Controller does not close or seat completely, check that the vent hole is not plugged.
  • D
    dustinharrisSep 18, 2025
    What to do if the diaphragm valve does not open on my MARLO MR-210-2?
    • A
      angelastanleySep 18, 2025
      If the diaphragm valve on your MARLO Controller does not open, check that the vent hole is not plugged.
  • J
    jeffrey22Sep 7, 2025
    What causes high flow to drain during service in MARLO Controller?
    • E
      Earl JonesSep 7, 2025
      If there is high flow to the drain during service with your MARLO Controller, check the position dial. If it is not in position #4, rotate the stager clockwise to this position.
  • J
    Juan HendrixSep 4, 2025
    How to fix a format mismatch on my MARLO Controller?
    • C
      Cheryl YoungSep 4, 2025
      To resolve a format mismatch on your MARLO Controller where units have both U.S. and Metric formats, verify that all units have the same format selected, either all U.S. or all Metric.

Summary

Installation Instructions

Start-Up Instructions

Connecting Power and Verifying Settings

Steps for powering the controller and confirming initial system settings.

User Mode Programming Flow Chart

MX III Controller Operation

Manually Initiating a Regeneration

How to start a regeneration cycle manually using the controller.

Single (System 4) Programming and Ranges

Master Programming Mode Flow Chart

Master Programming Guide

Master Programming Guide - Display and Capacity Settings

Master Programming Guide - Regeneration Timing and Relays

Diagnostic Mode Flow Chart

Diagnostic Programming Guide

MX-III Controller Replacement Parts

Error Codes

Troubleshooting Softener - Detected and Programming Errors

Detected Errors

Addresses issues related to communication and unit errors.

Programming Errors

Covers errors arising from incorrect programming settings.

Troubleshooting Controller

Troubleshooting Softener - Common Issues

Slight Leak to Drain

Diagnosing minor leaks from the drain connection.

Failure to Draw Brine

Troubleshooting issues preventing brine from being drawn into the system.

Diaphragm Valve Closing Issues

Diagnosing problems with diaphragm valves not closing properly.

Troubleshooting Softener - Advanced Issues

Restricted or No Drain Flow During Backwash

Diagnosing and fixing issues with drain flow during backwash.

Loss of Softening Resin

Addressing instances where resin is found in drain or service lines.

Troubleshooting Controller - Common Errors

MARLO MR-210-2 Specifications

General IconGeneral
BrandMARLO
ModelMR-210-2
CategoryController
LanguageEnglish