50 MAC III Wash user manual
Warning messages
* Adjustment should only be carried out by a qualified service technician with Martin™ service
documentation.
** High temperature warnings are canceled as soon as temperature returns to normal. If temperature
reaches cutoff level, the warning is replaced by a cutoff error message.
Short code Full-text message
AIRS CHECK AIR FILTERS
The timer available in the SERVICE menu has reached the point for which the alarm was set.
BANK BANK NO ACCESS
Error unpacking firmware bank during/after software upload. Fixture will continue to operate on
existing firmware. Warning message is cleared by a successful software upload or at the next
power off/on cycle.
BATM BATTERY MODE
Switched to battery power source with limited functionality. Plug in power cable to restore full
function operation.
BDNA BARNDOOR NOT ADJUSTED
No barndoor adjustment data in EEPROM. Internal barndoors may be incorrectly adjusted*.
BT W BASE TEMP HIGH
At least one base PCB indicates temperature within 10% of maximum**.
DINA DIMMER NOT ADJUSTED
No dimmer adjustment data in EEPROM. Dimmer may be incorrectly adjusted*.
EEPR EEPROM INVALID
No connection or EEPROM data invalid.
FTNA FROST NOT ADJUSTED
No frost adjustment data in EEPROM. Frost filter may be incorrectly adjusted*.
FUSB USB UPLOAD
The fixture has been started in forced USB upload mode (the Escape button was held during
power up).
HOT LAMP HOT
Lamp strike fails. Pan and tilt are disabled temporarily to reduce the risk of falling fragments if the
lamp has exploded. Fixture will try to restrike lamp three times ar 20 second intervals. If lamp still
refuses to strike after three attempts, an LAER (Lamp Error) message is displayed.
HT W HEAD TEMP HIGH
One or more of the PCB's in the head is within 10% of maximum**.
INLK INVALID LICENSE KEY
Invalid license key entered. Warning is displayed and it is impossible to enter a license key for 10
seconds.
LTIM LAMP LIFETIME
Lamp life is within 10% of limit set in LAMP ON TIME → SET TIME ALERT in the control panel
menu or via RDM.
MALW MAINS LOW
Mains voltage is below acceptable level. The lamp may not be able to strike (if impossible to strike,
MALE error appears).
PAN A PAN NOT ADJUSTED
No pan adjustment data in EEPROM. Pan may be incorrectly adjusted*.
SHNA SHUTTER NOT ADJUSTED
No shutter adjustment data in EEPROM. Shutter may be incorrectly adjusted*.
TINA TILT NOT ADJUSTED
No tilt adjustment data in EEPROM. Tilt may be incorrectly adjusted*.
YT W YOKE TEMP HIGH
One or more of the PCB's in the yoke is within 10% of maximum**.
Table 4: Warning messages