24 Matrix ETERNITY NE Quick Start
Powering on ETERNITY NE
• Connect the power adapter to ETERNITY NE.
• Plug in the power adapter of ETERNITY NE into the power outlet.
• Switch on power supply and wait for the Reset Cycle to complete.
Reset Cycle
• Reset Cycle (Power-ON Self Test) takes about 2 minutes to finish.
• The power LED, PWR, is turned on and remains ON.
• When the system becomes stable after power on, the status LED, STS, blinks
Green (1 second ON, 1 second OFF).
• The LEDs of the DSS keys of the Digital Key Phone(s) attached to the system
are turned on in a sequence. The handshaking between DKP and ETERNITY
lasts for 5-6 seconds.
• At the end of the Reset Cycle, the system loads the default extension numbers,
the date and time. These will appear on the display of the DKP connected to
ETERNITY NE.
• Mobile Ports take about 3 minutes to get registered with the network.
You may now access the web-based programming tool, Jeeves, and configure
ETERNITY NE.