Comet Executive Gas Repair
7-37
Figure 7-33: Return ribbon tension adjustment in
the left endframe.
A
B
C
Return Ribbon Tension Spring
Replacement
Tension on the return ribbons is held by the
weight of the return ribbon guide assembly. There
is no adjustment.
There is a spring (Figure 7-33, A) attached
to the return guide assembly bearing in each
endframe which prevents the assembly from
bouncing too much. These springs may wear and
need periodic replacement.
Required Tools
Pliers
Wrenches: 7/16” (2)
Perform only when the unit is OFF
with power disconnected and COOL.
1. Turn power OFF at the main disconnect
switch.
2. Open both endframe doors.
3. Locate the tension spring (Figure 7-33, A).
There is one on each side of the machine.
4. Remove the bolt holding the lower part of
the spring in place (Figure 7-33, B).
5. Remove the spring from the upper bracket
(Figure 7-33, C) and replace with the new
one.
6. Repeat Steps 3 to 5 in the other endframe.
7. Close and secure both endframe doors.
WARNING
Never operate the unit unless
all safety covers are in place
and all safety equipment is
working correctly.
8. Start the unit and make sure the return
ribbons track straight.