Preventive Maintenance Comet Executive Gas
4-16
Check Gas Pressure
It is important to check the available gas
pressure to the unit during periods of peak
demand by other gas-heated equipment in the
laundry room or elsewhere at the facility. Gas
pressure to the unit may be reduced signicantly
at these times, which will interfere with the proper
operation of the burner.
For more information on checking the gas
pressure, refer to Gas Connection Checkout
on page 2-20.
Check Mechanical and Electrical
Connections
Required Tools
Clean cloth
Screwdriver
Voltmeter
Wrench set
Perform only when the unit is OFF
with power disconnected and COOL.
Heating, cooling, and normal vibrations
may cause connections to loosen over time.
Perform this procedure to check and tighten the
mechanical and electrical connections.
1. Turn power OFF at the main disconnect
switch.
2. Open both endframe doors.
3. Check and tighten all mechanical fasten-
ers.
4. Check the electrical components in both
endframes.
5. Check all electrical connections in the
electrical panel.
WARNING
Only a qualied electrician
should make or correct any
electrical connections in or
to the unit.
6. Connect a voltmeter between the unit’s
frame and a separate, known earth ground.
7. If there is a reading on the voltmeter, check
and repair the ironers ground connection.