The Reversing Drain Sequence
The drum is reversing while the water is drained.
Menu Item Description Default Limits
Drain Valve Only available on washers with both a normal Open and
normal Closed Drain valve.
1 1–2
RPM The suggested RPM depends on the Machine Type. See Table A-5
On Time The mechanical action, motor On Time.
(The suggested default values can be adjusted in the
Initialization Menu)
12 sec 1–99 sec
Off Time The mechanical action, motor Off Time.
(The suggested default values can be adjusted in the
Initialization Menu)
3 sec 1–99 min
Time The Reversing Drain Sequence Time.
(for 0 minutes the Reversing Drain sequence will be skipped)
(programmable in steps of 0.5 minutes)
0.5 min 0–15.0 min
Exit Return to Edit Program Menu.
Drain Extract No Drain Static Drain Reversing Drain