115
0: Chinese
1: English
This function is only enabled for configuring the operation panel of the LCD.
The setting of this function code determines the protection class of the drive parameters. The settings are
as follows:
0: All the data can be changed
1: Only the main set frequency digital setting (P02.05) and this function code can be changed
2: Only this function code can be changed
To change other function code settings, please set the value of this function code to be 0 first. When the
parameter is changed, to protect the parameter, you can set the desired protection class for it.
Fig. 6-1 Selection of key functions
Unit place: Used for manufacturer commissioning, reserved
Tens place: Function selection of the STOP/RESET key
It is used to set the function scope and working mode of the STOP/RESET key of the keyboard when it is
used as the stop key.
Selection of key functions 0~371FH (0100)
P00.04
Parameter protection setting 0~2 (0)
P00.03