Table 6-1 Working mode of operation panel
Unit place Function Description
0
Invalid in non-panel
control mode
The STOP key is valid only in the panel control mode
1
Stop in the stop mode
under the non-panel
control mode
Valid in the command channel of panel, terminal and serial port .
When this key is pressed, the drive will stop in the stop mode set by
P08.06.
2
Coast to stop in
non-panel control mode
In the panel command channel, when this key is pressed, the drive will stop
in the stop mode set by P08.06. In the terminal or serial port command
channel, when this key is pressed, the drive will coast to stop and display
Er.EFT fault.
Note
When the STOP/RESET key is used as the fault reset key “RESET”, it is enabled in all the running command
channels. Double click the STOP key to coast to stop. Double click the STOP key during running, the drive will
coast to stop and display Er.EFT fault.
Hundreds place: Function selection of the M key
When it is set as 0, the M key is disabled.
When it is set as 1, the M key is used as JOG key. In the operation panel command channel, press this
key and hold, the drive will run in real time JOG mode. Release this key, it will stop running in JOG mode.
When it is set as 2, the M key is used as the direction switching key FWD/REV. In the operation panel
command channel, it can be used to switch the output frequency direction on line.
When it is set as 3, the M key is used as the command channel switching key, which is enabled only in
the stop status. The command channel switching order is as follows:
Operation panel command channel (LED of M key on) terminal command channel (LED of M key off)
serial port command channel (LED of M key flash) operation panel command channel (LED of M key
on)
When it is set as 4, the M key is used as the command channel switching key, which is enabled in both
stop and running statuses. The switching order is as above.
Note
You need to press the ENTER/DATA key within 3 seconds after switching to the desired running command
channel circularly with the M key (Multi-functional key) so that it becomes enabled.
When it is set as 5, the M key is used as the Multi-functional panel locking key. Now, press the M key and
press the
key three times at the same time to lock the panel. The locking mode of the panel depends
on the thousands place of the function code. To unlock the panel, set the thousands place as 5, press the
M key and press the
key three times at the same time, then the panel will be unlocked. When this
place is set as 0, this is no panel locking function.
When it is set as 6, the M key is used as the emergency stop key. Under any command channel , once
this key is pressed, the drive will perform the emergency stop command (like the terminal emergency
stop function) during running.