EasyManua.ls Logo

Megmeet MV300 Series - Page 162

Default Icon
262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
162
Note
When terminal X6 is used as the common digital input terminal, this filtering time (P09.10) is enabled; when
terminal X6 is used as the high-speed pulse input terminal, the filtering time is P09.14.
When the digital input terminal X6 is used as the high-speed pulse input terminal, the maximum input
pulse frequency can be determined by this function code.
This function code defines three different central point modes when terminal X6 is used as the pulse
input.
Unit place: X6 central point selection
0: No central point. As shown in Fig.6-30.
Fig. 6-30 No central point mode
The values corresponding to the pulse input frequency are all positive.
1: Central point mode 1
Fig. 6-31 Central point mode 1
Pulse reference central point selection 0~20P09.13
Reserved 0P09.12
Maximum input pulse frequency of X6 0.1~100.0kHz (10.0 kHz)P09.11

Table of Contents

Related product manuals