174
The drive output voltage V
O
=V
f
+V
b.
Note
The output voltage offset function is enabled only under the V/F mode.
D: Output voltage
When this function is enabled under V/F mode, the drive output voltage V
O
and the output frequency are
mutually independent. The drive output voltage is not restricted by the V/F feature curve of Group P07,
but is determined by the analog input signal, as shown in Fig.6-45.
Fig. 6-45 Output voltage curve
The horizontal coordinate in the figure is the adjusted analog input signal, the vertical coordinate is the
drive output voltage value. When the input analog voltage is less than 0, the output voltage is 0.
E: Reserved
P10.02~P10.03 defines the channel filtering time constant for the filtering of the input signal. The longer
the filtering time is, the stronger the immunity becomes, but the slower the response will become. The
shorter the filtering time is, the faster the response becomes, but the weaker the immunity will become.
Analo
g
curve selection 0~2022H
(
0010H
)
P10.05
Reserved 0P10.04
AI2 filterin
g
time 0.000~10.000s
(
0.010s
)
P10.03
AI1 filterin
g
time 0.000~10.000s
(
0.010s
)
P10.02