Fig. 4-4    Operation example for locking the operation panel keys 
Key unlocking 
When all the keys on the operation panel are locked, they can be unlocked through the following operation: 
Press and hold the M key, and then press the 
∨ key for 3 times. 
  Note 
No matter how P00.04 is set before, the operation panel is in unlocking status upon the power-up of the drive.   
4.1.3.3 Operation panel self-detection 
Before using the operation panel, you can check if the digital tube, LED and key functions are normal through 
the self-detection function of the MV300 operation panel. Operate according to the following steps:   
1. Press and hold the ENTER/DATA key in the stop status, and then press the STOP/RESET key to enter 
the self-detection status.   
During the self-detection, the 5 LED digital tubes on the operation panel will turn on one by one, and then                   
all the LEDs will turn on, with the LED displaying “00000”.   
2. Press the 
∧ key, ENTER/DATA key, M key, ∨ key,    key, RUN key and STOP/RESET key in turn.   
  In normal situation, when the 
∧ key is pressed, the LED display will change from “00000” to “11111”, and  
change correspondingly following the key pressing, until it displays “77777” when the STOP/RESET key 
is pressed.   
    3. Press the MENU/ESC key, and the LED will return to the stop parameter display status. The               
self-detection is completed.   
The above operation steps are shown in Fig. 4-5.   
 
 
Fig. 4-5    Self-detection example of LED operation panel 
∧ 
ENTER
DATA 
STOP 
RESET
11111
00000
8.8.8.8.8
50.00 
MENU 
ESC 
STOP 
RESET
 RUN 
ENTER
DATA
 
50.00 
77777 
66666
22222
+
…
 
ENTER
DATA
> 
MENU 
ESC 
P00.04
0000
0000
P00.0050.00 
ENTER
DATA
MENU
ESC
M  ^ 
+
> 
0500
P00.05
50.00
50.00