4.1.3.4 Restore to leave-factory values
For example, set P00.05=2, the parameters will restore to the leave-factory values. The leave-factory value
setting will make the drive parameters restore to the leave-factory values.
1. In the stop parameter display status, press MENU/ESC key to enter the first level menu P00.00;
2. Press
∧ key to change P00.00 to P00.05;
3. Press the ENTER/DATA key to enter the menu;
4. Press the
∧ key to change 0 to 2;
5. Press the ENTER/DATA key to confirm the change and return the first level menu. The change is
successfully completed.
The above operation steps are shown in Fig. 4-6.
Fig. 4-6 Operation example of restoring leave-factory values
4.1.3.5 Setting the set frequency
For example, set P02.05=25.00Hz.
Example: To change the setting of function code P02.05 from 50.00Hz to 25.00Hz.
1. In the stop parameter display status, press MENU/ESC key to enter the first level menu P00.00;
2. Press the
key to select the second highest bit;
3. Press
∧ key to change P00.00 to P02.00;
4. Press the
key to select the unit place;
5. Press
∧ key to change P02.00 to P02.05;
6. Press the ENTER/DATA key to enter the second level menu;
7. Press the
∨ key to change 50.00 to 25.00;
8. Press the ENTER/DATA key to confirm the change and return the first level menu. The change is
successfully completed.
The above operation steps are shown in Fig. 4-7.
50.00 P00.00 P00.04
0
2
P00.0050.00
>
>
MENU
ESC
ENTER
DATA
MENU
ESC
ENTER
DATA