EasyManua.ls Logo

Megmeet MV300 Series - Page 96

Default Icon
262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
96
magnetic
adjustment
coefficient 1
adjustment
coefficient 1
P12.12
Low
intensity
magnetic
adjustment
coefficient 2
Low intensity
magnetic
adjustment
coefficient 2
0~10000 1 1000 ×
P12.13
Low
intensity
magnetic
control
mode
Low intensity
magnetic
control mode
0: Disable
1: Enable
1 1 ×
P12.14
Cooling fan
control
Fan control
0: Operate automatically
1: Fun operates continually during
power-up
2: Fun operates based on
command
Note: It will keep running for 3
minutes after power-off
1 2 × ×
P12.15 ~
P12.27
Reserved
Group P13: Multi-stage reference and simple PLC parameters
P13.00
Multi-stage
reference
property
setting
Multi-stage
reference
property
0: Multi-stage frequency reference
1: Multi-stage closed loop
reference
1 0 ×
P13.01
Multi-stage
reference 1
Multi-stage
reference 1
When it is Multi-stage frequency:
0.0%~100.0% corresponds to
“minimum frequency ~ maximum
frequency”
When it is Multi-stage closed loop
reference:
-100.0%~100.0% corresponds to
“-10V~+10V”
0.1% 10.0% ×
P13.02
Multi-stage
reference 2
Multi-stage
reference 2
0.1% 20.0% ×
P13.03
Multi-stage
reference 3
Multi-stage
reference 3
0.1% 40.0% ×
P13.04
Multi-stage
reference 4
Multi-stage
reference 4
0.1% 60.0% ×
P13.05
Multi-stage
reference 5
Multi-stage
reference 5
0.1% 80.0% ×
P13.06
Multi-stage
reference 6
Multi-stage
reference 6
0.1% 90.0% ×
P13.07
Multi-stage
reference 7
Multi-stage
reference 7
0.1% 100.0% ×
P13.08
Multi-stage
reference 8
Multi-stage
reference 8
0.1% 10.0% ×
P13.09
Multi-stage
reference 9
Multi-stage
reference 9
0.1% 20.0% ×

Table of Contents