98
3: Reserved
4: AI analog reference
5: Terminal PULSE reference
6: Process closed loop PID
7: Reserved
Tens place of LED:
0: FWD
1: REV
2: Determined by the running
command
Hundreds place of LED:
0: Acceleration/deceleration time
1
1: Acceleration/deceleration time
2
2: Acceleration/deceleration time
3
3: Acceleration/deceleration time
4
P13.18
Stage 1
running time
Stage 1
running time
0.0~6500.0 0.1 20.0 ×
P13.19
Stage 2
setting
Stage 2
setting
The same as stage setting 1 1 000 × ×
P13.20
Stage 2
running time
Stage 2
running time
0.0~6500.0
0.1 20.0
×
P13.21
Stage 3
setting
Stage 3
setting
The same as stage setting 1 1 000 × ×
P13.22
Stage 3
running time
Stage 3
running time
0.0~6500.0
0.1 20.0
×
P13.23
Stage 4
setting
Stage 4
setting
The same as stage setting 1
1 000
× ×
P13.24
Stage 4
running time
Stage 4
running time
0.0~6500.0
0.1 20.0
×
P13.25
Stage 5
setting
Stage 5
setting
The same as stage setting 1
1 000
× ×
P13.26
Stage 5
running time
Stage 5
running time
0.0~6500.0 0.1 20.0 ×
P13.27
Stage 6
setting
Stage 6
setting
The same as stage setting 1 1 000 × ×
P13.28
Stage 6
running time
Stage 6
running time
0.0~6500.0 0.1 20.0 ×
P13.29
Stage 7
setting
Stage 7
setting
The same as stage setting 1 1 000 × ×
P13.30
Stage 7
running time
Stage 7
running time
0.0~6500.0 0.1 20.0 ×