EasyManua.ls Logo

Megmeet SPS-NE Series - Page 114

Default Icon
163 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
114
Function
code
Name
Index-
Sub-index
Value range
Min. unit
Default
value
Menu
mode
Cha
nge
Q
B
P08.13
DC braking
delay at stop
2008-0Eh
0.00 to 10.00 s
0.01 s
0.00 s
×
P08.14
DC braking
current at stop
2008-0Fh
0.0% to 100.0% of rated
current of servo drive
0.1%
0.0%
×
P08.15
DC braking
time at stop
2008-10h
0.0 (no action)
0.01 to 30.00 s
0.01 s
0.00 s
×
P08.16
Restart
selection upon
power failure
2008-11h
0: Disabled
1: Enabled
1
0
×
×
P08.17
Waiting time
for restart
upon power
failure
2008-12h
0.0 to 3600.0 s
0.1 s
0.0 s
×
P08.18
Reverse
running
inhibition
2008-13h
0: Reverse running
allowed
1: Reverse running
inhibited (zero frequency
running when a reverse
running command is
input)
1
0
×
×
P08.19
FWD/REV
switchover
deadzone time
2008-14h
0.00 to 360.00 s
0.01 s
0.00 s
×
P08.20
FWD/REV
switchover
mode
2008-15h
0: Switchover after the
zero frequency
1: Switchover after the
startup frequency
1
0
×
×
P08.21
Dynamic
braking usage
ratio
2008-16h
0.0 to 100.0% (0: No
action)
0.1%
100.0%
×
P08.22
Braking startup
2008-17h
700 to 780
1
750
×

Related product manuals