115
Function
code
Name
Index-
Sub-index
Value range
Min. unit
Default
value
Menu
mode
Cha
nge
Q
B
voltage
P08.23
Deceleration
time for
emergency
stop
2008-18h
0.00 to 100.00 s
(0: Automatic fast
deceleration)
0.01 s
0.00 s
×
P09: Digital input and output parameters
P09.00 to
P09.07
DI1 to DI8
function
selection
2009-01h
to
2009-08h
0: No function
1: FWD
2: REV
3: External FWD jogging
control input
4: External REV jogging
control input
5 to 9: Reserved
10:
Acceleration/Deceleration
time terminal 1
11:
Acceleration/Deceleration
time terminal 2
12, 13: Reserved
14: Frequency increase
command (UP)
15: Frequency down
command (DN)
16: External fault NO input
17: External fault NC input
18: External interruption
NO contact input
19: External interruption
NC contact input
20: Frequency reference
1
1
89
85
90
60
57
72
22
×