119
Function
code
Name
Index-
Sub-index
Value range
Min. unit
Default
value
Menu
mode
Cha
nge
Q
B
P09.09
Terminal
UP/DN rate
2009-0Ah
0.01 to 99.99 Hz/s
0.01
1.00
×
P09.10
Terminal filter
time
2009-0Bh
0 to 500 ms
1
10
×
P09.11 to
P09.14
Reserved
P09.15
Input terminal
active mode
2009-10h
Binary
0: Positive logic active
1: Negative logic active
LED ones:
Bit0 to Bit3: DI1 to DI4
LED tens:
Bit0 to Bit3: DI5 to DI8
1
00
×
P09.16
Virtual input
terminal active
mode
2009-11h
Binary
0: Inactive
1: Active
LED ones:
Bit0 to Bit3: DI1 to DI4
LED tens:
Bit0 to Bit3: DI5 to DI8
1
00
×
P09.18
Open-collector
output terminal
DO1
2009-13h
0: Servo drive in running
(RUN)
1: Frequency reach signal
(FAR)
2: Non-zero speed
detection signal
3: Frequency-level
detection signal (FDT1)
1
30
×
P09.19
Open-collector
output terminal
DO2
2009-14h
1
25
×
P09.20
Open-collector
output terminal
2009-15h
1
16
×