133
Function
code
Name
Index-
Sub-index
Value range
Min. unit
Default
value
Menu
mode
Cha
nge
Q
B
display
selection at
stop
0: No display; 1: Display
LED ones:
Bit0: Reference frequency
(Hz)
Bit1: Operating speed
(R/MIN)
Bit2: Set speed (R/MIN)
Bit3: Bus voltage
LED tens:
Bit0: Operating line speed
(m/s)
Bit1: Set line speed (m/s)
Bit2: Analog closed-loop
feedback (%)
Bit3: Analog closed-loop
setting (%)
LED hundreds:
Bit3: Terminal state (no
unit)
Note: If all are zero, the
reference frequency will
be displayed by default.
P16.03
Line speed
coefficient
2010-04h
0.1% to 999.9%
Line speed = Actually
measured/Estimated
speed × P16.03
Set line speed =
Reference frequency ×
P16.03
0.1%
1.0%
×
P16.04
Rotation speed
display
coefficient
2010-05h
0.1% to 999.9%
Operating speed =
Actually
0.1%
100.0%
×