EasyManuals Logo

Megmeet SPS-NE Series User Manual

Default Icon
163 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #95 background imageLoading...
Page #95 background image
95
Function
code
Name
Index-
Sub-index
Value range
Min. unit
Default
value
Menu
mode
Cha
nge
Q
B
P01.14
High bits of
work (kWh)
2001-0Fh
0 to 65535*10000 kWh
10000
kWh
0
×
*
P01.15
Low bits of
work (kWh)
2001-10h
0 to 9999 kWh
1 kWh
0
×
*
P01.16
Bus voltage
2001-11h
0 to 800 V
1 V
0
×
*
P01.17
Operation
status of servo
drive
2001-12h
0 to FFFFH
Bit0: Running/Stop
Bit1: REV/FWD
Bit2: Zero speed running
Bit3: Accelerating
Bit4: Decelerating
Bit5: Running at constant
speed
Bit6: Pre-excitating
Bit7: Auto-tuning
Bit8: Overcurrent limited
Bit9: DC overvoltage
limited
Bit10: Torque limited
Bit11: Speed limited
Bit12: Servo drive in fault
Bit13: Speed control
Bit14: Torque control
Bit15: Position control
1
0000
×
*
P01.18
Digital input
terminal state
2001-13h
0 to FFH, 0: Off; 1: On
High-speed pulse
reference not refreshed
synchronously
1
00
×
*