96
Function
code
Name
Index-
Sub-index
Value range
Min. unit
Default
value
Menu
mode
Cha
nge
Q
B
P01.19
Digital output
terminal sate
2001-14h
0 to FH, 0: Off; 1: On
High-speed pulse output
not refreshed
synchronously
1
0
×
*
P01.20 to
P01.23
Reserved
P01.24
Sin/Cos CD
signal strength
2001-19h
0 to 20.48
0.01
0.00
×
*
P01.25
Process
closed-loop
reference
2001-1Ah
-100.0 to 100.0%
(relative to the full span)
0.1%
0.0%
×
*
P01.26
Process
closed-loop
feedback
2001-1Bh
-100.0 to 100.0%
(relative to the full span)
0.1%
0.0%
×
*
P01.27
Process
closed-loop
deviation
2001-1Ch
-100.0 to 100.0%
(relative to the full span)
0.1%
0.0%
×
*
P01.28
Process
closed-loop
output
2001-1Dh
-100.0 to 100.0%
(relative to the full span)
0.1%
0.0%
×
*
P01.29
Estimated
temperature of
motor
2001-1Eh
0 to 200℃
1℃
0
×
*
P01.30
Sync deviation
count of
EtherCAT bus
2001-1Fh
0 to 10000
1
0
×
*
P01.31
ASR controller
output
2001-20h
-300.0 to 300.0%
(relative to the rated
torque of motor)
0.1%
0.0%
×
*