99
Function
code
Name
Index-
Sub-index
Value range
Min. unit
Default
value
Menu
mode
Cha
nge
Q
B
P02.04
Source of main
frequency
reference
2002-05h
0: Digital setting 1:
Keypad
∧∨
1: Digital setting 2:
Terminal UP/DN
2 to 5: Reserved
6: Process closed-loop PID
7 to 10: Reserved
1
0
P02.05
Digital setting
of main
frequency
reference
2002-06h
P02.17 to P02.16
0.01 Hz
50.00
P02.06
Main and
auxiliary digital
frequency
control
2002-07h
LED ones: Store selection
of main digital frequency
0: Frequency stored upon
power failure
1: Frequency not stored
upon power failure
LED tens: Main digital
frequency control upon
stop
0: Frequency retained
upon stop
1: Frequency restored
upon stop
LED hundreds: Store
selection of auxiliary
digital frequency
0: Frequency stored upon
power failure
1: Frequency not stored
upon power failure
LED thousands: Auxiliary
digital frequency control
1
0000
×