EasyManua.ls Logo

Mercury MERCRUISER - Boat in the Water; Boat out of the Water; Three-Point Manual Drain System

Mercury MERCRUISER
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 6 - Storage
90-864197076 NOVEMBER 2008 Page 111
5. Allow the system to drain for a minimum of five minutes. We recommend leaving the drain system open while transporting
the boat or performing other maintenance.
6. Reinstall the blue drain plug in the thermostat housing.
7. Close the drain system by rotating the blue handle clockwise until it stops and install the blue drain plug, if removed. The
handle is fully seated when no red is visible. Do not overtighten the handle, as this action will create new threads.
8. Open the seacock (if equipped) or unplug and reconnect the water inlet hose before operating the engine.
Boat out of the Water
1. Place the boat on a level surface to ensure complete draining of system.
2. Rotate the blue handle counterclockwise until it stops (approximately two turns). The red on the handle shaft indicates that
the drain system is open. Do not overtighten the handle, as this action will create new threads.
a - Blue handle
3. Visually verify that water is draining. If water does not drain, remove the blue drain plug from the distribution housing and
drain manually.
a - Blue drain plug
b - Drain location ‑ orange or red
4.
Allow the system to drain for a minimum of five minutes. We recommend leaving the plugs out while transporting the boat or
performing other maintenance to ensure that all water is drained.
5. Close the drain system by rotating the blue handle clockwise until it stops or installing the blue drain plug. The handle is fully
seated when no red is visible. Do not overtighten handle, as this action will create new threads.
Three‑Point Manual Drain System
Boat in the Water
NOTE: Use this procedure if your engine is not equipped with an air‑actuated single‑point drain system or if the air‑actuated single
point drain system fails.
1. Close the seacock (if equipped) or remove and plug the water inlet hose.
a
6141
a
b
33152

Table of Contents