PM (Personality Module) 20.3
replacement
The PM on the SRB contains the Firmware.
The PM on the BTS contains the Firmware,
Oven Serial Number, Temperature
Calibration, Cooking Programs, Application
Icons and the Recipe Images.
With a new PM tted and casing retted, 20.3.1
switch on the oven and tap the screen to hold and
check the BTS and SRB versions (1) are the latest
release, if not, execute a Firmware update using the
latest versions. For details see ‘Firmware Updates’
(Servicing section).
Tap the top right of the screen to bypass the 20.3.2
preheat stage (2).
Enter the service password and select OK to 20.3.3
display the Settings menu, see (3).
Select the USB symbol (4).20.3.4
Slide the Merrychef badge upwards and insert 20.3.5
the USB Memory Stick into the slot (5).
Once the USB has stopped ashing, select the 20.3.6
required USB recipe symbol (6).
Select the Application Icons le to download 20.3.7
(7). Note; a tinted band over a le name indicates
the le is not valid for that oven.
Check the le information shown is correct 20.3.8
before selecting OK (8), if not, select ‘X’ and locate
the correct le.
When completed, select recipes to load the 20.3.9
cooking programs (9). Once the programs are
loaded the oven restarts.
Enter the Date & Time settings (10). For 20.3.10
details see under ‘Oven Control Settings’ (Product
Information section).
Turn the oven switch OFF/ON.20.3.11
Remove the USB and keep in a safe place. 20.3.12
Reposition the USB cover.