73
MSI/plessey
Read: For mat
Data
Digits
(Variable)
Checksum1
(Optional)
Checksum2
(Optional)
Checksum Verification: The MSI/Plessey has one or two
optional checksum digits. The checksum is presented 3
kinds of method Mod10, Mod10/10 and Mod 11/10.
The checksum1 and checksum2 will be calculated as the
sum module 10 or 11 of the data digits.
Checksum Transmission: By setting Enable, checksum1
and checksum2 will be transmitted upon your selected
checksum verification method.
Max./Min. code length: Refer to Max./Min. code length
of Code-39.
Truncate leading/ending: Refer to Truncate
leading/ending of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00
01
Checksum
Disable
Mod 10
00
(8110)
01
(8150/8250
/8310/8312)
Program