EasyManua.ls Logo

METER EM50 Series User Manual

METER EM50 Series
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
i
TABLE OF CONTENTS
1. Introduction .............................................................................................. 1
2. About the Em50 Logger Series ....................................................... 2
2.1 Em50 Logger Series Overview ....................................................................2
2.2 Specifications ............................................................................................2
2.3 Functionality .............................................................................................3
2.3.1 Reset Button .................................................................................... 3
2.3.2 Em50 Series Status Lights ............................................................... 3
2.3.3 Em50 Series Test Button .................................................................. 4
2.4 Software ....................................................................................................4
2.4.1 Em50 Series Data Logging Scheme .................................................. 5
2.4.2 Em50 Measurement Interval ............................................................5
2.5 How the Em50 Stores Data ........................................................................5
2.5.1 Data Storage Format ........................................................................5
2.5.2 Data Storage Size .............................................................................6
2.5.3 Measurement Span ..........................................................................6
2.5.4 Compatible Sensors .........................................................................6
3. Setup and Installation ........................................................................ 7
3.1 Installing the Batteries ..............................................................................7
3.2 Installing Software ....................................................................................7
3.3 Configuring in ECH20 Utility .......................................................................8
3.4 Field Installation ........................................................................................9
4. Software and Configuration ..........................................................10
4.1 ECH20 Utility Software Installation .........................................................10
4.2 Common Tasks in ECH20 Utility ............................................................... 11
13453-16
11.30.2019

Table of Contents

Other manuals for METER EM50 Series

Questions and Answers:

METER EM50 Series Specifications

General IconGeneral
Measurement ParametersVolumetric Water Content (VWC), Electrical Conductivity (EC), Temperature
Temperature Accuracy±1 °C
Connector Type3.5 mm stereo plug
IP RatingIP68
VWC Measurement Range0 to 100%
EC Measurement Range0 to 23 dS/m
Temperature Measurement Range-40°C to 60°C
Operating Temperature-40°C to 60°C
Power3.6V Lithium battery
Cable Length5 m (standard)
MemoryLogger dependent
Data Logging IntervalLogger dependent
Battery LifeLogger dependent
CommunicationLogger dependent
DimensionsLogger dependent
WeightLogger dependent

Summary

1. Introduction

2. About the Em50 Logger Series

2.1 Em50 Logger Series Overview

Overview of the Em50 series loggers, including models and general capabilities.

2.2 Specifications

Detailed technical specifications for the Em50 series loggers, covering ports, memory, and power.

2.3 Functionality

Details on the core functionalities of the Em50 series loggers, including buttons and indicators.

2.4 Software

Information on the software options available for the Em50 series loggers.

2.5 How the Em50 Stores Data

Explanation of how the Em50 logger stores collected sensor data and its format.

3. Setup and Installation

3.1 Installing the Batteries

Step-by-step guide for installing batteries in the Em50 series loggers.

3.2 Installing Software

Instructions for installing the ECH20 Utility software on a computer.

3.3 Configuring in ECH20 Utility

Guide to configuring logger parameters using the ECH20 Utility software.

3.4 Field Installation

Procedures for installing the Em50 and its sensors in the field.

4. Software and Configuration

4.1 ECH20 Utility Software Installation

Detailed steps for installing the ECH20 Utility software.

4.2 Common Tasks in ECH20 Utility

Common operations performed using ECH20 Utility, including configuration and data download.

4.3 ECH20 Utility Menus

Explanation of the different menus within the ECH20 Utility software.

4.4 ZENTRA Cloud

Overview of ZENTRA Cloud for remote data management and analysis.

5. Em50G Cellular Communication

5.1 METER Data Service

How the Em50G uploads data to METER Data Service for remote access.

5.2 Cellular Service

Information on cellular service providers and compatibility for the Em50G.

5.3 Cellular Coverage

Factors affecting cellular coverage and network compatibility for the Em50G.

5.4 Em50G Configuration and Settings

Steps to configure the Em50G for cellular communication and data uploads.

5.5 Communication Testing

How to test the cellular communication quality of the Em50G.

5.6 Downloading Data

Methods for downloading data from the Em50G via cellular connection.

6. Em50R Radio Telemetry

6.1 Transmit Radio Telemetry

Using Transmit mode for Em50R loggers to send data to a DataStation.

6.2 Two-Way Radio Telemetry

Establishing two-way communication with Em50R loggers for data and settings.

6.3 Radio Settings

Configuring radio channel and subchannel settings for Em50R network communication.

6.4 Radio Performance

Factors affecting radio range and performance for Em50R telemetry.

6.5 Connecting via Rm-1 Radio Modem

How to connect to an Em50R using the Rm-1 Radio Modem.

6.6 DataStation Networks

Setting up and configuring DataStations for receiving Em50R telemetry data.

6.7 Download Collected Data

Retrieving collected data from the DataStation for analysis.

6.8 Data Processing

Processing collected data using DataTrac 3 or ECH20 Utility.

7. Caring for the Em50

7.1 Replacing the Batteries

Procedure for replacing batteries in the Em50 series loggers to maintain operation.

7.2 Long-Term Maintenance

Routine checks for long-term maintenance of the Em50 logger.

8. Troubleshooting

8.1 Customer Support

Contact information and support resources for METER products.

8.2 Terms and Conditions

Overview of METER's terms and conditions for instrument usage.

Related product manuals