Page 10
Functional Principle, Technical Data
optoCONTROL CLS-K
2.3 Range / Scanning Range
One Way
3
Sensor
3
Fiber strand
ø mm
Range
mm (type)
1
Minimum target size
(type)
Fiber strand
ø mm
Scanning range
mm (type)
1 2
0.6 90 ≤ 0.05 0.6 ≤ 10
1.0 200 ≤ 0.1 1.0 ≤ 30
1.5 500 ≤ 0.1 1,5 ≤ 80
2.5 1700 ≤ 0.2 2.5 ≤ 165
3.0 2000 ≤ 0.3 3.0 ≤ 180
2.4 Functions
The sensor optoCONTROL CLS-K supports following functions:
- Precise and reliable detection of targets
- Low drift by transmitter monitoring, thereby particularly suitable for measurement tasks.
- High switching frequency and short response time
- Sensor monitoring possible via analog signal
- Scanning distance up to 200 mm
4
- Range up to 2 m
4
- Switching output: NPN, PNP, optocoupler, relays (depending on the model, see Chap. 2.5.1, see Chap.
2.5.2)
- Drop-out delay 5 - 100 ms adjustable (optional)
- Stable long-term behavior by controlling the transmitter diode emission
- Large selection of fiber optics available, see Chap. A 1
The amplifiers CLS-K-61/-63 offer the possibility of spreading a signal range particularly important for the
solution of application on the entire analog range.
1) With 90° angular sensor mechanism reduced range
2) Related on Kodak white 90 %
3) See catalog optoCONTROL CLS-K
4) Depending on the fiber strand diameter

Related product manuals