Page 26
Operation and Setting
optoCONTROL CLS-K
P1 potentiometer
1
S1 range switch LED
Near
Far
Fig. 18 Settings of the potentiometer P1 and range switch S1
6.2 Commissioning
After the assembly, set the range switch S1 on Near, see Fig. 18.
The warm-up time of the amplier is approximately 10 min.
6.2.1 Range Switching S1
Near In the case of overregulation of the amplifier (analog signal > 5 V), the sensitivity can be
reduced by the Near setting.
Far In the case of a too small scanning range /range an increase can be achieved by the Far
setting.
Shift the range switch S1 into the reverse position, if no Near or Far setting can be effected with the
sensitivity potentiometer.
Please use a different fiber optics or change the position of the fiber optics, if even with this measure
setting is not possible.
1) P1 = Potentiometer sensitivity