Page 25
Operation and Setting
optoCONTROL CLS-K
6.1.3 Models CLS-K-60 /-63 /-65
Measuring point GND
Measuring point U
Fig. 16 View on operating and display elements models CLS-K-60 /-63/ -65
P3 OFFSET
zero offset
1
P2 Additional amplification
1
(signal spreading)
P1 Potentiometer sensitivity
S1 Range switching
S2
Selecting switch analog output
1
1 = Basic function
0 - 10 mA (63)
2 = Output
0 - 20 mA (63)
LED green LED red
1 2
Measuring point GND
Measuring point U
Fig. 17 Operating and display elements models CLS-K-60 /-63/ -65
1) Not available with version CLS-K-60/-65