ZLR964222L Line Module User Guide
20
Microsemi Corporation Confidential and Proprietary
5.2.5 Tone Profile
The MID does not include any Tone Profiles.
5.2.6 Ringing Cadence Profile
The Ringing Cadence Profile sets the cadence that is associated with ringing. The default Mini-PBX ringing
cadence configuration is 2 second ON and 4 seconds OFF.
5.2.7 Tone Cadence Profile
The Tone Cadence Profile sets the cadence that is associated with call progress tones. These tones normally
include dial tone, ring back, busy, congestion and call waiting tones.The MID does not include any Tone Profiles.
5.2.8 Caller ID Profile
The Caller ID Profile sets the signaling that is used for on-hook and off-hook Caller ID. The MID does not include
any Caller ID Profiles.
5.3 Profiles Generated with Profile Wizard
As an alternative to using the default profiles that are provided on the MID, the user can create new ones or edit the
following profiles that are provided with the standard Profile Wizard distribution:
• ZLR964222_SM2_LITE_REV2_9.VPW
These files contain Device, AC, DC, and Ringing Profiles and are available for use with the VP-API-II Lite software.
Customers who execute a Software License Agreement (SLA) for the VP-API-II software will have access to the
following additional files as a part of the full VP-API-II license:
• ZLR964222_SM2_FULL_REV2_9.VPW
These files contain Device, AC, DC, Ringing, Tone, Cadence, and Caller ID for over 44 countries.