Installation Guide
See also: Changes to Passwords and User Names (see "Properties of User Names and
Passwords" on page 20)
Haltingthe SyncServer
Microsemi recommends shutting the operating system down before removing the power.
Using the keypad/display interface:
1.
Press the MENU button.
2.
Select 3) Shutdown.
3.
Select 1) Yes.
4.
Press the ENTER button.
5. When the display shows "System Stopped - OK to Turn Power Off Now!" turn the power
off.
Or, using the web interface:
1.
Go to the SERVICES - Startup page.
2.
Select Halt and click the APPLY button.
3. Wait approximately 30 seconds before removing power.
ConfiguringLAN1
During installation, the user configures LAN1 to gain access to the web interface. After log-
ging in to the web interface, the user can configure the remaining ports on the NETWORK - Eth-
ernet page.
The factory default settings for the LAN1 network port are as follows:
n IP Address:192.168.0.100
n Mask: 255.255.255.0
n Gateway: 0.0.0.0
Configure new network settings using the keypad on the front panel:
1.
Press the MENU button on the front panel.
2.
Using the number buttons, select 1) LAN1, then 1) Config, and configure the port as
needed.
3.
Check the new LAN1 settings by pressing the STATUS button repeatedly until "LAN1
STATUS" is shown.
Note: Using the keypad/display interface to configure LAN1, erases the previous settings for
all of the network ports.
Also see MENU Button.