24 Port Gigabit Ethernet PoE Switch User Manual Page 48 of 72
________________________________________________________________________
©2014 MICROSENS GmbH & Co. KG Hamm/Germany www.microsens.com
have the same community name, they don’t belong to the same group. Hence,
the requesting network management unit cannot access the device with different
community name via SNMP protocol; if they both have the same community
name, they can talk each other.
Community name is user-definable with a maximum length of 15 characters and
is case sensitive. There is not allowed to put any blank in the community name
string. Any printable character is allowable.
The community name for each function works independently. Each function has
its own community name. Say, the community name for Read only works for
Read function and can’t be applied to other function such as Write and Trap.
Default SNMP function: Disabled
Default community name for Read: public
Default community name for Write: private
Default community name for Trap: public
System Event:
The System Event trap enable here is used for the “Cold Boot” or “Warm Boot” of
System Event. Default is “Disabled”.
Port Event:
The Port Event Trap Enablebutton here is used for the “Link Up” or “Link Down”
of system Event. Default is “Disabled”.

Other manuals for Microsens MS400863M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Microsens MS400863M and is the answer not in the manual?

Microsens MS400863M Specifications

General IconGeneral
BrandMicrosens
ModelMS400863M
CategoryNetwork Router
LanguageEnglish

Related product manuals