Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527
www.midtronics.com
28
Chapter 8: Digital Multimeter DSS-5000 HD
Meter Specications
Meter Range
Resolution
Accuracy
Vdc 0 V–30 V 0.01 V ± 1% of reading + 0.05V
Vac 0 V–20 Vac 0.01 V ± 1% of reading + 0.05V
Adc Low 0 mA–70 A 0.01 A ± 2% of reading ± 0.1A
Adc High 0 A–700 A 0.1 A ± 2% of reading ± 0.1A
Aac Low 0 A–20 A 0.01 A ± 2.5% of reading ± 0.1A
Aac High 0 A–200 A 0.1A ± 2.5% of reading ± 0.1A
Accuracies are specied from 2% to 100% of range.
Meter Range
Resolution
Accuracy
Ohm 0Ω–1MΩ 1Ω ± 3.5% of reading
± 1Ω
Temperature -30˚C to 70˚C 1˚C ± 1˚C
Accuracy specication dened as
± (n% reading + [count * resolution]) at 77 °F.