Technical Information
16
PW 6xx7
Manual test► Weighing system
Calibration
Test
and pressing the OK button, the following screen will be displayed. At the
same time, the door will be unlocked automatically and can be opened.
Weighing system ► Calibration
Empty the drum. Press the 0kg button.
0kg
After approx. 10 seconds, press the 0kg button and the weighing system will
be calibrated for zero kilograms. The following screen will then be displayed:
Weighing system ► Calibration
Weighing system calibrated for 0kg.
0kg
After 0kg calibration, the machine must be calibrated for 25kg. This requires
placing an exact 25kg weight (e.g., 25 liters of water or a 25kg standard
weight) in the drum.
Weighing system ► Calibration
Place 25kg in the drum. Press the 25kg button.
25kg
After approx. 10 seconds, press the 25kg button and the weighing system will
be calibrated for 25kg. The following screen will then be displayed:
Weighing system ► Calibration
Weighing system calibrated for 25kg.
25kg
Followed by: