Technical Information
49
PW 6xx7
MDU fault # Possible cause Notes Indication in EW 235
display
Fault/Information
F4061 SER_MSG_CHIPKA
RTE_FEHLER
Chip card read/write fault Information
F4062 SER_MSG_CHIPKA
RTE_SCHALTER
“Chip card inserted" switch fault Information
F4063 SER_MSG_SPEICH
ERKARTE_FEHLER
Operating data module
read/write fault
Information
F4064 SER_MSG_KEINE_S
PEICHER_KARTE
Operating data module access
fault
Information
F4065 SER_MSG_DATENS
PEICHER
Data flash card access fault Information
F4066 SER_MSG_UHR_MO
DUL
Clock module provides signal
“0”
Information
F4067 SER_MSG_BEL_MO
DUL
Load module access fault
(weighing system)
Information
F4068 SER_MSG_FU_MOD
UL
EFU 235 data read fault Information
F4069 SER_MSG_NTC_GE
ZOGEN
Accessing extended service
mode permitted
Information
F4070 SER_MSG_Model Discrepancy between model
type set via coded plug on ELP
235, N1L_ST19 and saved
value in control
Information
F4071 SER_MSG_HEIZUN
GSTYP
Discrepancy between heating
type set via coded plug on ELP
235, N1L_ST19 and saved
value in control
Information
F4072 SER_MSG_FEHLER
_BAE
Write fault from ELP 235 to EW
235
Information
F4073 MSG_DUMMY_1 Vacant Information
F4074 MSG_DUMMY_2 Vacant Information
F4075 MSG_DUMMY_3 Vacant Information
F4076 MSG_DUMMY_4 Vacant Information
F4077 MSG_DUMMY_5 Vacant Information
F4078 MSG_DUMMY_6 Vacant Information
F4079 MSG_FLIP_FLOP_A
BGEFALLEN
Internal application Information
F4080 Selection-display
module BAE fault
EW 235 defective, no response
from EW 235 during
communication w/ ELP 235
Data fault! Call service
department if restart
does not work.
Fault
F4081 Multifunction module
EZL 235 with coding
1 registered, coding
not recognized
Coding plug missing, no
contact, registered information
different to coding, no
communication with EZL 235
W/out wash program in
progress: No display.
During wash program:
“Data fault! Limited
function. Dispensing
defective.”
Fault
F4082 Multifunction module
EZL 235 with coding
2 registered, coding
not recognized
Coding plug missing, no
contact, registered information
different to coding, no
communication with EZL 235
W/out wash program in
progress: No display.
During wash program:
“Data fault! Limited
function. Dispensing
defective.”
Fault
F4083 Multifunction module
EZL 235 with coding
3 registered, coding
not recognized
Coding plug missing, no
contact, registered information
different to coding, no
communication with EZL 235
Without wash program
in progress: No
display. During wash
program: “Data fault!
Limited function. WRG
module defective.”
Fault
F4084 Multifunction module
EZL 235 with coding
4 registered, coding
not recognized
Coding plug missing, no
contact, registered information
different to coding, no
communication with EZL 235
Without a wash
program in progress:
No display. During a
wash program either:
“Data fault! Limited
function. Dispensing
defective.”
Fault