Technical Information
62
PW 6xx7
MDU fault # Possible cause Notes Indication in EW 235
display
Fault/Information
F4265
FEHLER_FU_FRAMI
NG, EFU fault,
communication
fault between EFU
and ELP
Fault registered from frequency
converter control EFU 235. A
framing fault (a type of
transmission fault occurring with
data transmission) has occurred
during communication between
EFU 235 and ELP 235.
“Drive system fault!” Fault
F4266
FEHLER_FU_FREI_1
, EFU fault reserve
code
EFU fault code not yet
allocated.
Fault
F4267
FEHLER_FU_FREI_2
, EFU fault reserve
code
EFU fault code not yet
allocated.
Fault
F4268
FEHLER_FU_FREI_3
, EFU fault reserve
code
EFU fault code not yet
allocated.
Fault
F4269
FEHLER_POSITIONI
ERUNG_IN_STOPP,
fault at
clean/soiled side,
positioning at
program stop
Washing machine clean/soiled
side: Control detects a position
fault at program stop.
Fault
F4270
FEHLER_POSITIONI
ERUNG_IN_ENDE,
fault at clean/soiled
side, positioning at
program end
Washing machine clean/soiled
side: Control detects a position
fault at program end.
Fault
F4271
FEHLER_POSITIONI
ERUNG_NACH_NET
ZAUS,
fault at clean/soiled
side, positioning after
shutoff
Washing machine clean/soiled
side: Control detects a position
fault after shutoff in status
before or during a program.
Fault
F4272
FEHLER_TUERSCH
LOSS_RS,
fault in door lock,
clean side
Washing machine clean/soiled
side: Fault in clean-side door
lock 2A2. Note: The fault for
the door lock on the soiled
side, 1A2, is covered with the
“normal” door lock faults
(F4144 and following), like for
front-loaders.
Fault
F4273
FEHLER_MFM_RUS,
fault in clean/soiled
side multifunction
module
Washing machine clean/soiled
side: Module ELP 235 (1N1L)
does not recognize the
multifunction module with
coding 6 (EZL 235).
Fault
F4274
FEHLER_MFM_RUS
_IN_LAEUFT,
fault in clean/soiled
side multifunction
module during
program
Washing machine clean/soiled
side: Fault in EZL 235 with
coding 6 during a program.
Fault
F4275
FEHLER_SCHALTE
R_POSITION_REIN,
fault at position
switch, clean side
Washing machine clean/soiled
side: Module ELP 235 doesn't
detect switching by position
switch on clean side (while
drum is spinning). Possibly a
fault at position switch S55,
connection between S55 and
EZL 235, plug 45X, EZL 235.