No. Program Step Basic Options Setting Options Notes
15 Level stop 1 No
No
Water inlet takes place at same
time as program steps
Dispensing phase 1, Agitation
from level and Wash time 1.
Yes
Water is first taken in until
programmed water level is
reached. Control interrupts
further program operation until
this has occurred and then starts
drum agitation with settings
made for program step Agitation
from level. Wash time 1 step
starts after programmed level 1
has been reached or after time
set with program step Agitation
from level has elapsed.
16 Wash time 1 No
No No Wash time 1 carried out.
User-defined
Programmer sets drum agitation
for washing for a set duration
with set rhythm and speed. Time
selectable between 0 min 0 s and
99 min 59 s in 1-s steps. Rhythm
options “No”, “Normal”,
“Gentle+”, “Gentle” and “User-
defined”. With “User-defined”, on
time must be between “2 s” to
“99 s” and off time between “2 s”
and “99 s” with sum ≥ 15 s.
Speed options “No”, “Normal”,
“Drench” and “User-defined”.
“User-defined” selectable
between 20 rpm and 70 rpm in 1-
rpm steps.
17 Thermostop
No or lock
symbol (if No has
been
programmed
under Heating in
this table/block)
No
Heating begins when min. level is
reached. Program steps Wash
time 1 and Wash time 2 are
carried out without set tempera-
ture having to be reached.
Yes
Heating begins when min. level is
reached. Program step Wash
time 1 is carried out. Program
step Wash time 2 starts only
after set temperature has been
reached (Thermostop).
Disinfection
Heating begins when min. level is
reached. Program step Wash
time 1 is carried out. Program
step Wash time 2 starts only
after set temperature has been
reached (Thermostop). In
addition, if temperature drops
below lower level of programmed
hysteresis (e.g., due to peak-load
cut-out, additional water intake or
power interruption, etc.), control
returns to Thermostop phase and
program steps Wash time 2 and
Dispensing phase 2 restart
again.