. A complete Parts List is available at www.MillerWelds.com
OM-265 363 Page 14
SECTION 4 − INSTALLATION
4-1. Important Information Regarding CE Products (Sold Within The EU)
A. Information On Electromagnetic Fields (EMF) For All Equipment Covered In This Manual
! This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding
.
This equipment is built in accordance with EN 60974−1 and is intended to be used only in an occupational environment (where the general publi
c
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner’s Manuals for all components of the welding circuit for additional EMF exposure
information.
S The EMF assessment on this equipment was conducted at 0.5 meter.
S At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
ce-emf 1 2010-10
B. Information On Electromagnetic Compatibility (EMC) For DC 650/800 Amp Power Source Models
! This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low−
voltage supply system. There may be potential difficulties in ensuring electromagnetic compatibility in those locations, due to
conducted as well as radiated disturbances.
This equipment complies with IEC 61000−3−12 provided that the short−circuit power Ssc is greater than or equal to 7,612,853.78 at the interface
point between the user’s supply and the public system. It is the responsibility of the installer or user of the equipment to ensure, by consultation
with the distribution network operator if necessary, that the equipment is connected only to a supply with a short−circuit power Ssc greater than
or equal to 7,612,853.78.
ce-emc 1 2010-10
C. Information On Electromagnetic Compatibility (EMC) For DC 1000/1250 Amp Power Source Models
! This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low−
voltage supply system. There may be potential difficulties in ensuring electromagnetic compatibility in those locations, due to
conducted as well as radiated disturbances.
IEC/TS 61000−3−4 may be used to guide the parties concerned by the installation of arc welding equipment with an input current above 75 Amps
in a low-voltage network.
ce-emc 5 2010-10
4-2. Serial Number And Rating Label Location
The serial number and rating information for the power sources is located on the front or the rear of the machine. Use the rating labels to determine
input power requirements and/or rated output. For future reference, write serial number in space provided on back cover of this manual.