OM-265 363 Page 40
9-2. Routine Maintenance
! Disconnect and lockout/tagout input power before per-
forming maintenance or troubleshooting procedures.
n = Check Z = Change ~ = Clean l = Replace
* To be done by Factory Authorized Service Agent
Every
3
Months
l Unreadable Labels n l Weld Cables ~ Weld Terminals
Every
6
Months
OR
~ Inside Unit (monthly dur-
ing heavy service)
9-3. Fuse F1
802 295
! Disconnect and lockout/tag-
out input power before
checking or changing fuse.
1 Fuse F1 (See Parts List For
Rating)
Fuse F1 protects control transform-
er from overload. If F1 opens, weld
output and fan motor stops. Re-
place F1.
Close and secure access door.
1
Tools Needed:
3/8 in.

Table of Contents