21
6. Press START/STOP.
Registration or Test Failure
• See 'Wireless Installation' for examples of devices/objects that could be causing
signal interference. Make sure all such devices are temporarily switched off, then
reregister using the instructions below and retest the drain pump.
• Attempt to improve the signal strength by moving the drain pump transformer,
then reregister using the instructions below and retest.
• Shower STARTS, but drain pump is NOT RUNNING.
Solution.....Isolate power and remove shower cover. Check jumper
position inside shower cover is set to WIRELESS.
• Drain pump STARTS, but shower is NOT RUNNING.
Solution.....Shut down shower and drain pump and reregister using the instructions
below.
1. Power to shower OFF.
2. Push and hold PUMP SWITCH until light goes from GREEN to RED/GREEN.
3. Within 30 seconds turn power to shower ON.
4. Beep from shower.
5. PUMP SWITCH light changes to GREEN.
6. Turn on shower to conrm shower and pump are operating together.
8. Pump will START. Any delay will depend upon
the plumbing layout, but pump should start within
10 SECONDS.
9 . Pump and shower work normally.
A test failure is indicated by the following:
• Shower and pump stop.
• 1 beep and all lights ash 6 times.
R
7. Shower will START.