24
1st Beep (LONG) - Release START/STOP.
2nd Beep (SHORT) - Release FLOW.
4.
5. HIGH FLOW LIGHT FLASHES
This indicates shower is commissioning correctly.
Water ows for approximately 1 minute 20 seconds.
In some cases the cycle can take up to 3 minutes.
Allow shower to stop automatically.
IMPORTANT! DO NOT INTERRUPT THE CYCLE!
6. Push START/STOP to turn shower ON.
Check that maximum temperature is
acceptable to the user.
COMMISSIONING FAILURES
(the commissioning cycle was stopped due to an error)
No ashing FLOW LIGHT... solution ...Restart the commissioning cycle.
No water after 5 seconds... solution ...Reprime the shower. (See "Installation".)
WATER SUPPLY or
RESET light is on................ solution ...Reprime the shower. (See "Installation".)
_
+
7. Push START/STOP to turn shower OFF.
Wait until water has stopped flowing
BEFORE turning Power/Electric OFF.
8. Residual water may drain over a few
minutes.
OFF