BEAB CARE IN-SERVICE TESTS
The following procedure applies to products operated and maintained within the BEAB Care
requirements. This procedure should be conducted by designated, qualied and competent
personnel only.
To maintain the validity of the BEAB Care mark, regular inspections of the installation and
appliance should be carried out. The purpose of the in-service tests is to monitor and record
the performance of the shower. Any deterioration in performance can indicate the need for
maintenance work on the appliance and/or the water supplies.
Frequency of Inspections
Upon the initial installation of the shower and after any major repair work (e.g. Renewing
the Flow Valve or Heater Tank etc...), the in-service tests must be performed and the results
recorded on the BEAB Care In-Service Test Record to provide a reference point for future
inspections. (The BEAB Care In-Service Test Record is on page 34 and 35).
The shower should be inspected again within 6 to 8 weeks after installation or any major repair.
If there is no signicant change in the outlet water temperature greater than ±1 ºC between
the two inspections, the in-service test frequency may be reduced but must not exceed 12
months between any two inspections.
Equipment Required
The following equipment or suitable equivalent will be required in order for the tests to be
performed:
Digital Multimeter (crocodile clip probes are recommended)
100 mm diameter plastic funnel
Digital liquid thermometer accurate to 0.1 ºC
2 - 22 l/min ow measure cup
Cup or container suitable for catching water
BEAB Care In-Service Test Record
Installation Address:
Location of Shower:
Maximum Temperature Setting:
(maximum of 41 ºC for showering)
Installed by:
Please record all test results on this form, including details of all measurement equipment used. This form is available to download at www.mirashowers.co.uk.
1178847-W9-B © Kohler Mira Limited, August 2011
Date:
Not Operating Normal Operation Restricted Supply
Date /
Signature
Terminal
Block
Voltage
(V)
Inlet
Water
Temp.
(ºC)
Inlet
Filter
Cleaned
Terminal
Block
Voltage
(V)
Outlet
Water
Temp.
(ºC)
Flow
Rate
(l/min)
Outlet
Water
Temp.
(ºC)
Flow
Rate
(l/min)
Equipment Details
(make, model, serial number, calibration date etc...)