2-31 Options
Robot arm
(2) Changing the operating range
Order type: J1 axis.....1S-DH -02
Outline
The operating range of J1 axis is limited by the robot arm's mechanical stopper and
the controller parameters.
If the axis could interfere with the peripheral devices, etc., and the operating range
need to be limited, use this.
Configuration
Table 2-15 Configuration devices
Specifications
Table 2-16 Specifications
(1) The changeable angle shown in Table 2-16 indicates the operation range by the software.
The limit by the mechanical stopper is positioned 1 degrees outward from that angle, so take care when
designing the layout.
(2) The changeable angle can be set independently on the + side and - side.
(3) The operating range is changed with robot arm settings and parameter settings. Refer to the separate
"Instruction Manual/ROBOT ARM SETUP & MAINTENANCE" or "Instruction Manual/Detailed Explanation
of Functions and Operations" for details.
Part name Type Qty. Mass(kg) Remarks
Stopper for changing the operat
-
ing range of J1
1S-DH-02 2 pcs. 0.1 Hexagon socket bolt: M12 x 20 plating (strength classi
-
fication 10.9)
Axis Standard Changeable angle
J1
+ side +170 degree One point from +135°, +90°, +45°
- side -170 degree One point from -135°, -90°, -45°