3-45 Names of each part
3 Controller
Fig.3-3 : Operation lock of the power switch(CR3D-700)
Usage of lock function
① Turn the handle to the reset direction
until the mark of the lock plate and the
case mark is in match.
② Push in the lock plate.
③ Return the handle to the OFF position,
with pushing the lock plate.
④ Lock the handle with the padlock.
Case mark
Lock plate
Handle
Padlock (prepare by customer)
Dimension of the padlock
The maximum size of "C" which can be installed is 8mm.
Dimension (mm)
ABC
35(0.11) 19 5
40(0.13) 22 or 23 5.5
The lock device which can be used
< CR3D-700 series >