3-49 Names of each part
3 Controller
Fig.3-7 Installation to the Ethernet cable of ferrite core and filter (CE Marking specification)
The installation conditions of the ferrite
core and the line noise filter
Outside dimension of the line noise filter
Line noise filter(attachments)
Pass 8 times
Robot controller
500mm or less
To external equipment
Ferrite core
(attachments)
Pass twice
Note1)
100mm or less
Note 1) CR1D/CR2D: The dimension from the connector of the controller
   CR3D: The dimension from the controller chassis.
Ethernet cable
Note1) CR1DA/CR2DA: The dimension from the connector of the controller.
CR3D: The dimension from the controller chassis.