15
2 SERVO AMPLIFIER SETTING
2.3 Ethernet Parameter Settings
5.
Set as shown below. After the parameters are set, check the connection to the servo amplifiers by clicking
[Communications Test]. When the connection has succeeded, click [OK].
*1 For the fourth octet of IP addresses, the values set by the rotary switches in the step 1 are used. Thus, the IP addresses are as shown
below.
Station number 1: 192.168.3.1
Station number 2: 192.168.3.2
When the communication test detects a connection failure, perform the following.
• Check the power supplies of the programmable controller and the servo amplifiers, wiring with Ethernet cables.
• Check the IP address and the subnet mask of the personal computer.
• Initialize the servo amplifiers.
For how to initialize servo amplifiers, refer to the following.
MR-JET-G User's Manual (Introduction) [4.6 Servo amplifier setting initialization]
Item Setting value
Axis 1 Axis 2
Connection Network CC-Link IEF Basic
Via None
PC side I/F Protocol UDP
Time-out 1s
Retry 0 times
Servo Amplifier Configuration Model MR-JET-G MR-JET-G
IP address
*1
192.168.3.1 192.168.3.2